Railway Cables | ||||||||||||
1.8/3KV Single Core Dual Wall Traction Cables
Application
Single core power and control cable designed for protected, fi xed installation inside and outside railway vehicles for connecting fi xed and moving parts in direct current and alternating voltage technology, especially converter technology
Standards
● BS 6853 -1a
● DIN 5510-1 1-4
● NFF 16-101 F0
Construction
Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
Insulation1
Electron beam crosslinkable thin wall LSZH compound.
Insulation2
Electron beam crosslinkable thin wall LSZH compound.
Screen(optional)
Copper Wire Screen (for screened and sheathed cables).
Outer Sheath(optional)
Electron beam crosslinkable LSZH compound (for screened and sheathed cables).
Optional
FRA-DW-3SU-FR(Fire resistant & Unsheathed)
Electrical Characteristics at 20℃
Nominal Conductor Cross Section | mm² |
1.5 |
2.5 |
4.0 |
6.0 |
10 |
16 |
25 |
35 |
50 |
Maximum Conductor Resistance | Ω/km |
13.7 |
8.21 |
5.09 |
3.39 |
1.95 |
1.24 |
0.795 |
0.565 |
0.393 |
Voltage Rating | KV |
1.8/3 |
Nominal Conductor Cross Section | mm² |
70 |
95 |
120 |
150 |
185 |
240 |
300 |
400 |
Maximum Conductor Resistance | Ω/km |
0.277 |
0.21 |
0.164 |
0.132 |
0.108 |
0.0817 |
0.654 |
0.0495 |
Voltage Rating | KV |
1.8/3 |
Mechanical and Thermal Properties
Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃
Dimensions And Weight
FRA-DW-3SU (Unsheathed)
Cable Code |
No. of cores& Nominal Conductor Cross Sectional Area No.×mm² |
Nominal Diameter of Strands No/mm |
Nominal Insulation Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
FRA-DW-3SU-1G1.5 |
1×1.5 |
30/0.25 |
0.8 |
3.2 |
22 |
FRA-DW-3SU-1G2 |
1×2.0 |
37/0.25 |
0.9 |
3.55 |
28 |
FRA-DW-3SU-1G2.5 |
1×2.5 |
50/0.25 |
0.9 |
3.75 |
34 |
FRA-DW-3SU-1G4 |
1×4.0 |
56/0.30 |
1.0 |
4.50 |
52 |
FRA-DW-3SU-1G6 |
1×6.0 |
84/0.30 |
1.1 |
5.10 |
74 |
FRA-DW-3SU-1G10 |
1×10.0 |
80/0.40 |
1.2 |
6.35 |
120 |
FRA-DW-3SU-1G16 |
1×16.0 |
126/0.40 |
1.5 |
8.30 |
180 |
FRA-DW-3SU-1G25 |
1×25.0 |
196/0.40 |
1.8 |
10.20 |
280 |
FRA-DW-3SU-1G35 |
1×35.0 |
276/0.40 |
2.0 |
11.70 |
390 |
FRA-DW-3SU-1G50 |
1×50.0 |
396/0.40 |
2.2 |
13.60 |
550 |
FRA-DW-3SU-1G70 |
1×70.0 |
360/0.50 |
2.1 |
15.60 |
730 |
FRA-DW-3SU-1G95 |
1×95.0 |
475/0.50 |
2.3 |
17.30 |
940 |
FRA-DW-3SU-1G120 |
1×120.0 |
608/0.50 |
2.4 |
19.60 |
1180 |
FRA-DW-3SU-1G150 |
1×150.0 |
756/0.50 |
2.6 |
21.90 |
1510 |
FRA-DW-3SU-1G185 |
1×185.0 |
925/0.50 |
2.8 |
23.80 |
1800 |
FRA-DW-3SU-1G240 |
1×240.0 |
1221/0.50 |
2.9 |
26.90 |
2290 |
FRA-DW-3SU-1G300 |
1×300.0 |
1525/0.50 |
3.0 |
29.70 |
2910 |
FRA-DW-3SU-1G400 |
1×400.0 |
2013/0.50 |
3.4 |
35.80 |
4040 |
FRA-DW-3S-OS (Screened & Sheathed)
Cable Code |
No. of cores& Nominal Conductor Cross Sectional Area No.×mm² |
Nominal Diameter of Strands No/mm |
Nominal Insulation Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
FRA-DW-3S-OS-1G1.5 |
1×1.5 |
30/0.25 |
0.8 |
5.2 |
48 |
FRA-DW-3S-OS-1G2.5 |
1×2.5 |
50/0.25 |
0.9 |
5.8 |
63 |
FRA-DW-3S-OS-1G4 |
1×4.0 |
56/0.30 |
1.0 |
6.7 |
89 |
FRA-DW-3S-OS-1G6 |
1×6.0 |
84/0.30 |
1.1 |
7.4 |
120 |
FRA-DW-3S-OS-1G10 |
1×10.0 |
80/0.40 |
1.2 |
9.0 |
180 |
FRA-DW-3S-OS-1G16 |
1×16.0 |
126/0.40 |
1.5 |
11.2 |
280 |
FRA-DW-3S-OS-1G25 |
1×25.0 |
196/0.40 |
1.8 |
13.4 |
400 |
FRA-DW-3S-OS-1G35 |
1×35.0 |
276/0.40 |
2.0 |
14.8 |
510 |
FRA-DW-3S-OS-1G50 |
1×50.0 |
396/0.40 |
2.2 |
16.8 |
700 |
FRA-DW-3S-OS-1G70 |
1×70.0 |
360/0.50 |
2.1 |
19.0 |
920 |
FRA-DW-3S-OS-1G95 |
1×95.0 |
475/0.50 |
2.3 |
20.7 |
1160 |
FRA-DW-3S-OS-1G120 |
1×120.0 |
608/0.50 |
2.4 |
23.4 |
1450 |
FRA-DW-3S-OS-1G150 |
1×150.0 |
756/0.50 |
2.6 |
25.9 |
1830 |
FRA-DW-3S-OS-1G185 |
1×185.0 |
925/0.50 |
2.8 |
27.8 |
2130 |
FRA-DW-3S-OS-1G240 |
1×240.0 |
1221/0.50 |
2.9 |
31.2 |
2910 |
FRA-DW-3S-OS-1G300 |
1×300.0 |
1525/0.50 |
3.0 |
34.2 |
3370 |